• Floor Standing Split 30kw Precision Air Conditioner for Data Center
  • Floor Standing Split 30kw Precision Air Conditioner for Data Center
  • Floor Standing Split 30kw Precision Air Conditioner for Data Center

Floor Standing Split 30kw Precision Air Conditioner for Data Center

Type: Split Air Conditioner
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
Operating Voltage: 380/400 VAC
Noise Level: Ordinary
Application Fields: Data Center
Samples:
US$ 5500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
RGAC-30
Mounting
Floor Standing
Lifetime
5~10 years
Certification
ISO, CCC
Condition
New
Indoor Air Supply
7200m3/H
Outdoor Air Supply
12000m3/H
Rated Frequency
50Hz
Rated Power
12.4
Rated Current
19.0
Maximum Input Current
24.0
Refrigerant Quantity
6.5kg
Refrigerant
R22
Indoor Dimentsion
806*735*2150mm
Outdoor Dimentsion
1760*543*1031mm
Transport Package
Wooden Case or Customized
Specification
30kw
Trademark
Langji or OEM
Origin
Suzhou China
Production Capacity
15000 Pieces/Year

Product Description

Product Feature
 
  1. Langji company's patented product.
  2. Air condition and heat pipe share a same system, which greatly improve the efficiency of air conditioning and heat pipe.
  3. Air condition and heat pipe system can switch automatically, at the same time the machine can be remote monitored.
  4. Energy saving effect is obvious.
  5. Digital temperature controler and high precision of temperature control.   
  6. Main components have CE certificates, which can meet EU ROHS requirements.
  7. Module machine design combines each freely according to the room space make it convenient for transportation and installation.
Floor Standing Split 30kw Precision Air Conditioner for Data Center
Floor Standing Split 30kw Precision Air Conditioner for Data Center


Technical Parameters
 
Model RGAC-6500-2 RGAC-8500-3 RGAC-12500-3 RGAC-20 RGAC-30 RGAC-60
Rated Voltage(V) 220VAC±10% 50Hz 380VAC±10% 50Hz
Rated Power(KW) 2.3 2.8 4.1   9.6 19.2
Cooling Capacity(KW) 6.9 9.1 13.2 20 30 60
Heat Exchange Capacity(KW)(T=10ºC) 3.2 4.0 6.5   10 20
Refrigerant R134A/R22
Work Temperature Range(ºC) -20~+45
Weight(Kg) 220 260 310     520
Color RAL7035
IP Grade IP23
Ambient Air Circuit(m3/h) 4500 4800 6300   9800 19600
Cabinet Air Circuit(m3/h) 3400 4500 5200   7200 14400
                  
Dimension L*W*H (mm)         
Indoor Unit 850×650×2000 850×650×2000 850×650×2000   850x850x2000 1700x850x2000
Outdoor Unit 1025×1085×600 1025×1085×600 1065*1235*600   1510x410x932 (1510x410x932)x2

Application
Floor Standing Split 30kw Precision Air Conditioner for Data Center

Company Profile
Established in 2009, Langji Technology provides full range of temperature control products and solutions for telecommunication industry. The annual production of temperature control unit is 60,000 pcs, outdoor cabinet 15,000 units.

Langji owns more than 10 patents, strictly follow ISO9001 and ISO14001, the workshop include sheet metal cutting, punching, bending, welding, air conditioner assembling and cabinet assembling.

The products are certified by CE, they have been widely used by many well-know companies such as China Mobile and China Unicom, furthermore, we have successfully entered Europe, South-east Asia, Middle East, South America and the USA.  

Today Langji has been the leader in the industry, sincerely look forward to cooperating with you!
Floor Standing Split 30kw Precision Air Conditioner for Data Center
Certification
Floor Standing Split 30kw Precision Air Conditioner for Data Center
Our Exhibition
Floor Standing Split 30kw Precision Air Conditioner for Data Center

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
77
Year of Establishment
2009-10-15